Product Information and Technical Data

 #202 Aluminum Emulsion is a UL Rated, technologically advanced, high quality reflective coating that provides a tough layer of protection over roof surfaces. #202’s brilliant aluminum finish reflects the sun’s rays to help lower interior temperatures and preserve the roof surfaces. This professional grade coating can be applied over virtually any type of roof surface (including damp surfaces). It contains built-in rust inhibitors and is easy to mix and apply. This is a water based coating. #202 is non-polluting, non-toxic and non-combustible. Equipment can also be cleaned faster using water thus eliminating costly down time.

Uses
#202 is
a reflective roof coating for; Modified Bitumen, Built-up, Smooth surface emulsion coatings, Metal, Asphalt, Parapet Walls, Flashings, Exposed piping and ducts, Stucco, Polyurethane Foam, and Other approved surfaces

Advantages
#202 r
educes indoor building temperatures in summer by reflecting the sun's rays. It is self-preserving. Its aluminum armor reflects most of the rays of the sun which oxidize and age the asphalt base below.

Installation
Coverage

Product yield will be from 75 to 100 square feet per gallon per coat. The yield varies according to the existing surface texture. As a general rule, the smoother the surface, the less material is required.

Surface Preparation
Remove all dirt, dust, debris and standing water by brooming and by forced air where necessary and where no danger or nuisance is caused to areas adjacent to work. All loose gravel must be removed from ballasted roofs. Scrape back to a hard edge all loose or scaled coating. Make all necessary repairs to existing surface prior to coating. Split seams, blisters and cracks in existing surface should be repaired with Roof Cement. Heavily weathered or exposed felt surfaces, as well as concrete, masonry, or weathered metal should receive an application of Asphalt Primer prior to coating. All surfaces must be dry prior to application.

Application
Coating must be thoroughly stirred prior to and occasionally during use. Mechanical mixing, if practical, is recommended. Apply by spray with a standard mastic pump and gun sized by a knowledgeable pump dealer for the particular application or by pouring directly from the container and spreading with a soft roofing brush or long nap roller. Brush or roll product out uniformly and evenly, taking care not to overwork it.

#202 cleans up with soap and water when wet. If dried, clean tools with paint thinner or mineral spirits.

For the easiest workability in cold temperatures, warm containers by storing them overnight in a room at 65° to 75° F.

Drying Time:
Four hours to touch at 70° F. & 50% relative humidify.

Spray Info: 1000-2000 psi, .061 Tip Size, 3-6 GPM (topcoat), 2-4 GPM (BUR)

Restrictions
Minimum application temperature is 40° F. and rising. Do not apply to areas which pond water; do not use on dead level, tar base, or existing gravel roofs. Do not apply to new asphalt roofs which have cured less than 30 days, solvent based asphalt coatings less than 30-90 days old, or to asphalt emulsion coatings that have cured for less than 30 days. Surfaces to be coated must be dry and clean and must remain so for 24 to 48 hours after application. Light rain or heavy dew will inhibit the leafing of the aluminum flakes, causing the product to dry brown.
Do not use with PVC film. Do not use where material, once applied, may come into contact with potable water. Not for use on or with products containing coal tar. Do not use on slate shingles or apply directly to wood surfaces. Not for use over rubber or plastic membranes - asphalt modified only. For exterior use only.

Cautions
This product is combustible. Keep away from heat, sparks and open flame. Avoid repeated or prolonged contact with skin. If swallowed, do not induce vomiting, Contact Physician Immediately. Keep container closed when not in use. KEEP AWAY FROM CHILDREN. Product label and Material Safety Data Sheet contain further information on the safe use of this product and precautions for the safe disposal of the container. They should be read and understood prior to use.

SPECIFICATIONS

Weight Per Gallon

8.8-9.3 lbs.

Residue by Evaporation %

28 min.

Combustible Solvents

N/A

Consistency

Brush, Spray, Roller

Cure time

4-8 hours to set

24-48 hours to full

Application temperature

50°F - 100°F

Flammability

N/A

Reflectivity

62%

PACKAGING INFORMATION

Product Number

Size

Quantity

Weight

202-055

55 gal.

Each

535 lbs.

202-005

5 gal.

Each

47 lbs.

 

Availability and Costs:

Availability: Products are immediately available from GlobalShield, Inc. throughout the United States.

Cost: Cost data is available from your local GlobalShield representative.

Technical Services: GlobalShield Technical Services Department provides problem analysis and assistance in developing recommendations for special applications.  Warranty systems require inspection by GlobalShield prior to installation. Progress and final inspections are also required.

Statement of Policy and Responsibility:

GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.


GlobalShield, Inc.

320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723
Email: solov@global-shield.com
Web site: www.global-shield.com

Home Up #170 #311 #310 #204 #203 #202 #200 Contact Us