#129 Elastomeric Asphalt Emulsion is a rubberized roof coating that can be applied over virtually any type of roof surface. This professional grade, watertight coating forms a seamless barrier that will withstand water. Its elastomeric properties and superior bonding ability produce an outstanding base coat of protection for almost any roof condition. #129 actually expands and contracts with the roofs surface to resist peeling, cracking and checking. It can be applied to modified bitumen, built-up, asphalt, shingles, metal, concrete and even old tar roofs. Roof coated with #129 form an excellent base for all GlobalShield reflective coatings.
Preparation
All surfaces must be clean, have proper drainage and be free of surface rust and
any other foreign matter. Roof surface may be damp (from morning dew), however
surfaces may not be saturated with water. Brush clean all cracks, holes and
damaged or rusted areas with wire brush. Repair using GlobalShield polyester
reinforcement and #129.
For best results, reinforce coating with a polyester reinforcing fabric or chopped glass fibers. Once cured, apply #310 Bright White Elastomeric Roof Coating or #202 Aluminum Emulsion. This will greatly extend the life of the roof.
Application
Protective clothing and eyewear should be used during application of
this product. Always apply on a clear, warm sunny day. Apply morning hours to
allow maximum cure time. Temperatures must be above 50°F
and rising, but not above 110°F.
Apply using professional airless sprayer, brush or ½ to Ύ nap roller.
Covers approximately 50-75 s.f. per gallon. Two coats are recommended. Allow 4-8
hours between coats. Coverage rates may vary depending on texture of surface.
Spray Info: 500-1000 psi., 0.055 Tip Size, 3-6 GPM (topcoat), 2-4 GPM (BUR)
Precautions: Do not store at temperatures below 50°F. Keep closed when not in use. Then transporting this product ensure that lid is tight and pail secured. Do not allow pair to tumble as this may cause lid to loosed and leakage to occur. The manufacturer also disclaims liability for flat surface application where poor drainage or ponding of water may prevail. Do not reuse empty container. Dispose of in an environmentally acceptable manner.
Physical
Characteristics
|
Elongation |
110-150% |
|
Tensile Strength |
150-200 psi. |
|
Adhesion to Polyurethane Foam |
Excellent |
|
Weight per gallon |
8.4-8.9 lbs. |
|
Color |
Black |
|
Residue by Evaporation |
46% min. |
|
Combustible Solvents |
None |
|
Consistency |
Spray or Brush |
|
Cure Time |
4-8 hours to set |
|
Application Temperatures |
50°F to 120°F |
|
Flammability |
None |
|
Clean up Tools |
Warm water and soap |
|
Approximate Shipping Weights |
5 gallon pails 45 lbs. 55 gallon drums 513 lbs. |
Cautions: Harmful or fatal if swallowed. Keep out of reach of children. Call physician in case of: Ingestion Drink water, induce vomiting. Eye contact Flush with plenty of warm water. Skin contact Wash thoroughly with soap and water. Irregular or stopped breathing administer oxygen, give artificial respiration. Get medical attention (immediately). Avoid prolonged breathing of vapor or spray mist. (NIOSH/MSHA TC 23C or equivalent.
Availability
and Costs:
Availability:
Products are immediately available from GlobalShield, Inc. throughout the United
States.
Cost:
Cost
data is available from your local GlobalShield representative.
Technical
Services:
GlobalShield
Technical Services Department provides problem analysis and assistance in
developing recommendations for special applications.
Warranty systems require inspection by GlobalShield prior to
installation. Progress and final inspections are also required.
Statement
of Policy and Responsibility:
GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.

GlobalShield,
Inc.
320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723
Email:
solov@global-shield.com
Web site: www.global-shield.com