Product Information and Technical Data

#125 No Fiber Roof Coating is a high quality coating manufactured with specially selected asphalts and additives. It penetrates, resaturates and revitalizes old, dry roofing felts. Designed for use on all types of smooth surface roofs, it forms a durable, weatherproof surface. Easily applied by brush or spray, it remains pliable, increasing roof service life

Uses 
#125 No Fiber Roof Coating may be used as a
base coat for a final coat of Aluminum or Asphalt Fibered Coating. It may also be used as a weatherproof surface coating for metal roofs. It also forms a weatherproof surface coating for roof masonry surfaces and gutters.

Advantages

Installation
Coverage 

Product yield to achieve desired rate will be from 1 to 3 gallons per 100 square feet. The yield varies according to the existing surface texture. As a general rule, the smoother the surface, the less material is required. Recommended application rate is 12 to 36 mils wet film thickness that will produce 8 to 24 mils dry. A mil is 1/1000 of an inch.

Surface Preparation 
Remove all dirt, dust, debris and standing water by brooming and by forced air where necessary and where no danger or nuisance is caused to areas adjacent to work. All loose gravel must be removed from ballasted roofs. Scrape back to a hard edge all loose or scaled coating. Make all necessary repairs to existing surface prior to coating. Split seams, blisters, and cracks in existing surface should be repaired with GlobalShield
Roof Cement and reinforced with GlobalShield Polyester. Metal roofs should be allowed to weather for six months prior to coating.

Application 
Apply by spray with a standard mastic pump and gun sized by a knowledgeable pump dealer for the particular application or by pouring directly from the container and spreading with a standard roofing brush. Be sure to spread product evenly.

#125 No Fiber Roof and Metal Coating cleans up with mineral spirits, but do not thin the product with this or any other solvents.

For the easiest workability in cold temperatures, warm containers by storing them overnight in a room at 65° to 75° F.

Drying Time:
Four hours to touch at 70° F. & 50% relative humidify. Allow 7 to 14 days before any exposure to foot traffic.

Restrictions 
Do not use with PVC film. Do not use where material, once applied, may come into contact with potable water. Not for use on or with products containing coal tar. Do not use on slate shingles or apply directly to wood surfaces. Surfaces to be dry and clean and must remain so for 24 to 48 hours after application. Not for use over rubber or plastic membranes - asphalt modified only. For exterior use only.

Cautions 
This product is combustible. Keep away from heat, sparks and open flame. Avoid repeated or prolonged contact with skin. If swallowed, do not induce vomiting, Contact Physician Immediately. Keep container closed when not in use. KEEP AWAY FROM CHILDREN. Product label and Material Safety Data Sheet contain further information on the safe use of this product and precautions for the safe disposal of the container. They should be read and understood prior to use.

SPECIFICATIONS

Percent Solids by Weight

68%

Percent Solids by Volume

63%

Weight Per Gallon: Pounds

7.7

Flash Point

105° F (Seta C.C.)

P.H.

N/A

Viscosity at 77° F.

800 cps.

Long-Term Service Temperature

-25° F. to +155° F.

Water Resistance: Intermittent Exposure

Excellent

Water Resistance: Ponded

Fair

Solvent Resistance

Poor

U.V. Resistance

Good

 PACKAGING INFORMATION

Product Number

Size

Quantity

Weight

125-055

55 gal.

Each

490 lbs.

125-005

5 gal.

Each

40 lbs.

 

Availability and Costs:

Availability: Products are immediately available from GlobalShield, Inc. throughout the United States.

Cost: Cost data is available from your local GlobalShield representative.

Technical Services: GlobalShield Technical Services Department provides problem analysis and assistance in developing recommendations for special applications.  Warranty systems require inspection by GlobalShield prior to installation. Progress and final inspections are also required.

Statement of Policy and Responsibility:

GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied.  Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.


GlobalShield, Inc.

320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723
Email: solov@global-shield.com
Web site: www.global-shield.com