#124
Asphalt Roof Resaturant is a
carefully formulated blend of refined asphalts, mineral fibers and penetrating
oils. Specifically designed for the continued growth of bitumen as replacements
for coal tar in flat roof construction, #124 Asphalt Roof Resaturant penetrates
the existing asphalt roof mat and gives new life to the old asphalt. In addition
to these restorative properties, a heavy layer of asphalt remains on the roof
surface as a protective coating or as binder for new roof ballast.
Uses
#124 Asphalt Roof Resaturant is use for dead
level and mildly sloped gravel and slag ballasted roofs. Dried out level or
mildly sloped modified bitumen roof surfaces.
Advantages
Installation
Coverage
Product yield to achieve desired rate will be from 7 to 10 gallons per 100
square feet. The yield varies according to the existing surface texture. As a
general rule, the smoother the surface, the less material is required.
Recommended application rate is 84 to 120 mils wet film thickness that will
produce 41 to 58 mils dry. A mil is 1/1000 of an inch. . Requires installation
of new gravel at the approximate rate of 450-500 pounds per 100 s.f.
Surface
Preparation
Remove all dirt, dust, debris and standing water by brooming and by forced air
where necessary where no danger or nuisance is caused to areas adjacent to work.
All loose gravel must be removed from ballasted roofs. Scrape back to a hard
edge all loose or scaled coating. Make all necessary repairs to existing surface
prior to coating. Split seams, blisters and cracks in existing surface should be
repaired with GlobalShield Roof
Cement and reinforced
with GlobalShield Polyester.
Application
Apply by spray with a standard mastic pump and gun sized by a knowledgeable pump
dealer for the particular application or by pouring directly from the container
and spreading with a standard roofing brush. Be sure to spread product evenly.
#124 Asphalt Roof Resaturant cleans up with mineral spirits, but do not
thin the product with this or any other solvents.
For the easiest workability in cold temperatures, warm containers by
storing them overnight in a room at 65° to 75° F.
Drying Time: Four hours to touch at 70° F. & 50% relative humidify.
Restrictions
Do not use with PVC film. Do not use where material, once applied, may come into
contact with potable water. Not for use on or with products containing coal tar.
Do not use on slate shingles or apply directly to wood surfaces. Surfaces to be
dry and clean and must remain so for 24 to 48 hours after application. Not for
use over rubber or plastic membranes - asphalt modified only. For exterior use
only.
Cautions
This product is combustible. Keep away from heat, sparks and open flame. Avoid
repeated or prolonged contact with skin. If swallowed, do not induce vomiting,
Contact Physician Immediately. Keep container closed when not in use. KEEP AWAY
FROM CHILDREN. Product label and Material Safety Data Sheet contain further
information on the safe use of this product and precautions for the safe
disposal of the container. They should be read and understood prior to use.
SPECIFICATIONS
|
Percent
Solids by Weight |
68%
|
|
Percent
Solids by Volume |
70%
|
|
Weight
Per Gallon: Pounds |
7.8
|
|
Flash
Point |
105°
F (Seta C.C.) |
|
P.H.
|
N/A
|
|
Viscosity
at 77° F. |
8,000
cps. |
|
Long-Term
Service Temperature |
-60°
F. to +160° F. |
|
Water
Resistance: Intermittent Exposure |
Excellent
|
|
Water
Resistance: Ponded |
Fair
|
|
Solvent
Resistance |
Poor
|
|
U.V.
Resistance |
Good
|
PACKAGING
INFORMATION
|
Product
Number |
Size |
Quantity |
Weight |
|
124-055 |
55
gal. |
Each |
490
lbs. |
|
124-005 |
5
gal. |
Each |
42
lbs. |
Availability: Products are immediately available from
GlobalShield, Inc. throughout the United States.
Cost:
Cost data is available from your
local GlobalShield representative.
Technical
Services: GlobalShield
Technical Services Department provides problem analysis and assistance in
developing recommendations for special applications.
Warranty systems require inspection by GlobalShield prior to
installation. Progress and final inspections are also required.
Statement
of Policy and Responsibility:
GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.

GlobalShield,
Inc.
320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723
Email: