#120 Asphalt Fibered Roof Coating is a tough, high quality coating manufactured with specially selected asphalts, mineral fibers, plasticizers, and other additives. It applies easily by brush or spray and displays unusually strong bonding and penetrating qualities. Applied as directed, it cures to a durable, weatherproof roof surface with excellent long-term flexibility. It increases roof service life and helps preserve old, dried out roof surfaces.
Uses
#120 Asphalt Fibered Roof Coating
is a weatherproof surface coating for built up or composition roofs. It may also
be used as a weatherproof surface coating for metal roofs as well as masonry
surfaces and gutters.
Advantages
Installation
Coverage
Product yield to achieve desired rate is 2 to 10 gallons per 100 square feet.
Yield varies according to the existing surface texture. As a general rule, the
smoother the surface, the less material is required.
Smooth surface
built-up roofs – 2.5 to 5 gallons per 100 s.f. Gravel surface built-up roofs
– 7 to 10 gallons per 100 s.f. Apply approximately 450 pounds of new gravel
per 100 s.f. while coating is still wet. Metal roofs – 2 to 3 gallons per 100
s.f.
Surface
Preparation
Remove all dirt, dust, rust, debris, and water by brooming and by forced air
where necessary and where no danger or nuisance is caused to areas adjacent to
work. All loose gravel must be removed from ballasted roofs. Scrape back to a
hard edge all loose or scaled coating. Make all necessary repairs to existing
surface prior to coating. Splits, seams, blisters, cracks in existing surface
and flashings should be repaired with #102 Roof
Cement or #110 Asphalt Mastic
and reinforced with Polyester.
Heavily weathered or exposed felt surfaces, as well as concrete, masonry, or
rusted metal should receive an application of #101 Asphalt
Primer prior to coating. All
surfaces must be dry prior to application.
Application
Apply by spray with a standard mastic pump and gun sized by a knowledgeable pump
dealer for the particular application or by pouring directly from the container
and spreading with a standard roofing brush. Be sure to spread product evenly.
#120 Asphalt
Fibered Roof Coating cleans up with mineral spirits, but do not thin the product
with this or any other solvents.
For the easiest workability in cold temperatures, warm containers by storing
them overnight in a room at 65° to 75° F.
Drying Time: Four hours to touch
at 70° F. & 50% relative humidify. Allow 7 to 14 days before any exposure
to foot traffic.
Restrictions
Do not use with PVC film. Do not use where material, once applied, may come into
contact with potable water. Not for use on or with products containing coal tar.
Do not use on slate shingles or apply directly to wood surfaces. Surfaces to be
dry and clean and must remain so for 24 to 48 hours after application. Not for
use over rubber or plastic membranes - asphalt modified only. For exterior use
only.
Cautions
This product is combustible. Keep away from heat, sparks and open flame. Avoid
repeated or prolonged contact with skin. If swallowed, do not induce vomiting,
Contact Physician Immediately. Keep container closed when not in use. KEEP AWAY
FROM CHILDREN. Product label and Material Safety Data Sheet contain further
information on the safe use of this product and precautions for the safe
disposal of the container. They should be read and understood prior to use.
SPECIFICATIONS
|
Percent
Solids by Weight |
69%
|
|
Percent
Solids by Volume |
65%
|
|
Weight
Per Gallon: Pounds |
8
|
|
Flash
Point |
105°
F (Seta C.C.) |
|
P.H.
|
N/A
|
|
Viscosity
at 77° F. |
12,000
cps. |
|
Long-Term
Service Temperature |
-60°
F. to +160° F. |
|
Water
Resistance: Intermittent Exposure |
Excellent
|
|
Water
Resistance: Ponded |
Fair
|
|
Solvent
Resistance |
Poor
|
|
U.V.
Resistance |
Good
|
PACKAGING
INFORMATION
|
Product
Number |
Size |
Quantity |
Weight |
|
120-055 |
55
gal. |
Each |
450
lbs. |
|
120-005 |
5
gal. |
Each |
42
lbs. |
Availability:
Products are immediately available from GlobalShield, Inc. throughout the
United States.
Cost:
Cost data is available from your
local GlobalShield representative.
Technical
Services: GlobalShield
Technical Services Department provides problem analysis and assistance in
developing recommendations for special applications.
Warranty systems require inspection by GlobalShield prior to
installation. Progress and final inspections are also required.
Statement
of Policy and Responsibility:
GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.

GlobalShield,
Inc.
320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723