#101 Asphalt Primer is a premium quality blend of asphalts and solvents formulated to penetrate, soften and tenaciously adhere to old, dry roofing felts. Applied as directed, Asphalt Primer provides a sound base for the application of asphalt coatings, emulsions, adhesives and cements. Asphalt Primer is also designed for use on weathered metal and previously uncoated concrete roofs. Meets all specifications of ASTM D41-88.
Uses
#101 Asphalt Primer is used to
promote adhesion on built up roofs and exposed or dry felts. Use on weathered
metal and all previously uncoated concrete roofs. Use on any roof application
where adhesion problems may occur.
Advantages
#101 Asphalt Primer promotes
adhesion to badly weathered roof surfaces. Provides a sound base for the
application of roof coatings. Economical and easy to use
Installation
Coverage
Product yield to achieve desired rate will be from .75 to 1 gallon per 100
square feet. The yield varies according to the existing surface texture. As a
general rule, the smoother the surface, the less material is required.
Recommended application rate is 8 to 12 mils wet film thickness that will
produce 4 to 6 mils dry. A mil is 1/1000 of an inch.
Surface
Preparation
Remove all dirt, dust, debris and standing water by brooming and by forced air
where necessary and where no danger or nuisance is caused to areas adjacent to
work. All loose gravel must be removed from ballasted roofs. Scrape back to a
hard edge all loose or scaled coating.
Application
Apply Asphalt Primer by airless spray or pump and gun sized by a knowledgeable
pump dealer or by pouring directly from the container and spreading with a
standard roofing brush. It can also be paintbrush applied. On dusty areas, a
brush should be used to work the material into the surface.
#101 Asphalt Primer cleans up with mineral spirits, but do not thin the product
with this or any other solvents.
For the easiest workability in cold temperatures, warm containers by storing
them overnight in a room at 65° to 75° F.
Drying Time: Two to Four hours
to touch at 70° F. & 50% relative humidify.
Allow Asphalt Primer to penetrate and set for a full four hours before applying
solvent based coatings and 24 hours before applying emulsion products.
Restrictions
Do
not use with PVC film. Do
not use where material, once applied, may come into contact with potable water.
Not for use on or with products containing coal tar. Do
not use on slate shingles or apply directly to wood surfaces. Surfaces
to be dry and clean and must remain so for 24 to 48 hours after application. Not
for use over rubber or plastic membranes - asphalt modified only. For
exterior use only.
Cautions
This product is combustible. Keep away from heat, sparks and open flame. Avoid
repeated or prolonged contact with skin. If swallowed, do not induce vomiting,
Contact Physician Immediately. Keep container closed when not in use. KEEP AWAY
FROM CHILDREN. Product label and Material Safety Data Sheet contain further
information on the safe use of this product and precautions for the safe
disposal of the container. They should be read and understood prior to use.
SPECIFICATIONS
|
Percent
Solids by Weight |
52%
|
|
Percent
Solids by Volume |
48%
|
|
Weight
Per Gallon: Pounds |
7.4
|
|
Flash
Point |
105°
F (Seta C.C.) |
|
P.H.
|
N/A
|
|
Viscosity
at 77° F. |
25-125
S.F.S.. |
|
Long-Term
Service Temperature |
N/A
|
|
Water
Resistance: Intermittent Exposure |
Fair
|
|
Water
Resistance: Ponded |
Poor
|
|
Solvent
Resistance |
Poor
|
|
U.V.
Resistance |
Poor
|
PACKAGING
INFORMATION
|
Product
Number |
Size
|
Quantity
|
Weight
|
|
101-055
|
55
gal. |
Each
|
475
lbs. |
|
101-055 |
5
gal. |
Each
|
40
lbs. |
Availability: Products are immediately available from GlobalShield, Inc. throughout the United States.
Cost:
Cost data is
available from your local GlobalShield representative.
Technical
Services: GlobalShield
Technical Services Department provides problem analysis and assistance in
developing recommendations for special applications.
Warranty systems require inspection by GlobalShield prior to
installation. Progress and final inspections are also required.
Statement
of Policy and Responsibility:
GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.

GlobalShield,
Inc.
320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723