Product Information and Technical Data

PRODUCT DESCRIPTION: 
#150 Hot Rubberized Adhesive is a blend of high performance asphalt and Shell Kraton G (SEBS) polymer. It serves as a quality mopping asphalt for use in the construction of built-up roof membrane assemblies. #150 Hot Rubberized Adhesive may be used as an interply adhesive with all GlobalShield ply sheets, as a surfacing flood coat, or as a waterproofing membrane in IRMA Systems and Garden Roof Systems.

AREAS OF USE: 

BENEFITS:

INSTALLATION:

  1. Surface Preparation: Surface prepared to project specification must be clean and dry.

  2. Heating: #150 Hot Rubberized Adhesive must be heated in a conventional roofing kettle to a minimum temperature of 400 °F. In order to achieve a consistent temperature of #150 Hot Rubberized Adhesive during application, the kettle should be equipped with a circulating pump. #150 Hot Rubberized Adhesive may be applied in a temperature range (EVT) of 425°F ± 25°F when mopping and 450°F ± 25°F when using a mechanical spreader. Avoid heating above 525°F. The flash point of #150 Hot Rubberized Adhesive is above 550°F. 

  3. When working with coated and uncoated ply sheets, the application temperature of the #150 Hot Rubberized Adhesive must not exceed 400°F to avoid distortion of polyester. 

  4. Add material #150 Hot Rubberized Adhesive and plastic wrap to the kettle. Allow #150 Hot Rubberized Adhesive to melt at least 20 minutes before pumping in order to completely melt the plastic wrapper and modified asphalt material. 

  5. Application: #150 Hot Rubberized Adhesive may be applied by mop, using cotton or fiberglass mop heads. Felt layers, such as Garlock Universal, can be used. Chain mops are not to be used with uncoated polyester ply sheets, as they can damage the ply. 

  6. Final Surfacing: As surfacing floodcoat of #150 Hot Rubberized Adhesive is applied (see Coverage Rates), broadcast a minimum of 400 lbs. of new, clean roof gravel per 100 sq. ft. into wet flood coat. 

COVERAGE RATES: 

PACKAGING: 
#150 Hot Rubberized Adhesive is packaged in cartons weighing approximately 42 lbs., or 4 3/4 gallons; 48 cartons per pallet. Each pallet is weighed to assure the proper quantities of material are shipped. Each package of material is wrapped in meltable plastic to facilitate handling at the kettle. 

STORAGE LIFE: One (1) year since storage conditions are beyond our control and may have a negative affect on 

COLOR: Black 

PRECAUTIONS: 
Read MSDS and label before use.
Follow industry safety standards when working with #150 Hot Rubberized Adhesive. Follow cold weather guide lines when required for working with hot material.

Kettle should circulate material during heating process. Not designed for smooth surface finish. Polymer modified asphalts hold their temperature longer than standard asphalts; therefore, kettle temperature may need to be kept lower to maintain the proper EVT at application. Recommend that a sandbox be available for roofing crews' shoes to reduce sticking and asphalt build-up. For industrial/commercial use only. Keep out of reach of children

Technical Data:

PROPERTY

TYPICAL VALUE

TEST METHOD

Softening Point

180-205°F

ASTM D 36

Flash Point

550°F or greater

ASTM D 92

Penetration

25-35 units, 250C

ASTM D 5

Ductility

25 cm, 25°C

ASTM D 113

Elongation

500% or greater

ASTM D 412

Tensile Strength

100 psi

ASTM D 412

Cold Temperature Bend

0°F, no cracks

ASTM D 3111

Density

1.0 minimum

ASTM D 70

Penetration Index

3.0

Calculated Value

Fire Resistance

Pass, Class A

ASTM E 108/UL 790

Asbestos Content

096

EPA 600/M4-82-020

Compatibility with Type VI Glass Ply Sheet and 

Coated Glass, Polyester and Glass/Polyester Sheets 

Oliensis Test, no exudate

ASTM D 1370

Average Adhesion Strength to Felt Coating After Conditioning:

24 Hrs. @ 158°F 

7 Days  @ 158°F

30 Days 0 158°17 


5.1 lb/in.

5.4 lb/in.

4.2 lb/in.

ASTM D 1876

 

Availability and Costs:

Availability: Products are immediately available from GlobalShield, Inc. throughout the United States.

Cost: Cost data is available from your local GlobalShield representative.

Technical Services: GlobalShield Technical Services Department provides problem analysis and assistance in developing recommendations for special applications.  Warranty systems require inspection by GlobalShield prior to installation. Progress and final inspections are also required.

Statement of Policy and Responsibility:

GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.


GlobalShield, Inc.

320-P North Point Parkway
Acworth, GA 30102
800-374-7663
770.974.2499
Fax: 770.974.2723
Email: solov@global-shield.com
Web site: www.global-shield.com

Home Up #107 #131 #143+#144 #150 #160 Contact Us