 PRODUCT DESCRIPTION:
GlobalShield Roofing Asphalt serves as a quality mopping asphalt for use in the construction of built-up roof membrane assemblies. GlobalShield Roofing Asphalt may be used as an interply adhesive with all GlobalShield ply sheets, as a surfacing flood coat, or as a waterproofing membrane in IRMA Systems and Garden Roof Systems.

AREAS OF USE:

BENEFITS:


INSTALLATION:

Surface Preparation: Surface prepared to project specification must be clean and dry.

Heating: GlobalShield Roofing Asphalt must be heated in a conventional roofing kettle to a minimum temperature of 400 °F. In order to achieve a consistent temperature during application, the kettle should be equipped with a circulating pump. GlobalShield Roofing Asphalt is applied in a temperature range (EVT) ± 25°F when mopping or ± 25°F when using a mechanical spreader. Avoid heating above 475°F

When working with coated and uncoated ply sheets, the application temperature of the GlobalShield Roofing Asphalt must not exceed 400°F to avoid distortion of polyester.

Application: GlobalShield Roofing Asphalt may be applied by mop, using cotton or fiberglass mop heads. Felt layers, such as Garlock Universal, can be used. Chain mops are not to be used with uncoated polyester ply sheets, as they can damage the ply.

Final Surfacing: As surfacing floodcoat of GlobalShield Roofing Asphalt is applied (see Coverage Rates), broadcast a minimum of 400 lbs. of new, clean roof gravel per 100 sq. ft. into wet flood coat.

COVERAGE RATES:

PACKAGING: GlobalShield Roofing Asphalt is packaged in cartons weighing approximately 100 lbs. Each pallet is weighed to assure the proper quantities of material are shipped.

STORAGE LIFE: One (1) year since storage conditions are beyond our control and may have a negative affect on

COLOR: Black

PRECAUTIONS: Read MSDS and label before use. Follow industry safety standards when working with Hot Asphalt Adhesive. Follow cold weather guide lines when required for working with hot material.

Kettle should circulate material during heating process.  Polymer modified asphalts hold their temperature longer than standard asphalts; therefore, kettle temperature may need to be kept lower to maintain the proper EVT at application. Recommend that a sandbox be available for roofing crews' shoes to reduce sticking and asphalt build-up. For industrial/commercial use only. Keep out of reach of children

Technical Data:

PROPERTY
ASTM 312-95a

TYPICAL VALUE – Type III

TYPICAL VALUE – Type IV

TEST METHOD

Softening Point

185-205°F

210-225°F

ASTM D 36

Flash Point

475°F or greater

475°F or greater

ASTM D 92

Penetration

15-35 units @ 77°F

12-25 units @ 77°F

ASTM D 5

Ductility

2.5 @ 77°F

1.5 @ 77°F

ASTM D 113

 

Availability and Costs:

Availability: Products are immediately available from GlobalShield, Inc. throughout the United States.

Cost: Cost data is available from your local GlobalShield representative.

Technical Services: GlobalShield Technical Services Department provides problem analysis and assistance in developing recommendations for special applications.  Warranty systems require inspection by GlobalShield prior to installation. Progress and final inspections are also required.

Statement of Policy and Responsibility: GlobalShield takes responsibility for the furnishing of quality materials, and providing specifications and recommendations for their proper installation. GlobalShield does not, either itself or through its representative, practice architecture or engineering. GlobalShield offers no opinion on, and expressly disclaims any responsibility for, the structural soundness of any roof deck on which its products may be applied. Opinions of competent structural engineers should be obtained by the owner as to the structural soundness of the roof deck, or its ability to properly support the contemplated roof installation. GlobalShield accepts no liability for any failure of the roof deck or resultant damages, and no GlobalShield representative is authorized to vary this disclaimer.